{"product_id":"lc1d40a6bd","title":"LC1D40A6BD Schneider","description":"\u003cp\u003eTeSys Deca contactor, 3 poles (3NO), for motor control applications up to 40A\/690V AC-3\/3e (18.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles\/hour and environments until 60Â°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.04 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of Product\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor application\u003c\/td\u003e\n\u003ctd\u003eResistive load\u003cbr\u003eMotor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilisation category\u003c\/td\u003e\n\u003ctd\u003eAC-4\u003cbr\u003eAC-1\u003cbr\u003eAC-3\u003cbr\u003eAC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit \u0026lt;= 690 V AC 25...400 Hz\u003cbr\u003ePower circuit \u0026lt;= 300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ie] rated operational current\u003c\/td\u003e\n\u003ctd\u003e60 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-1 for power circuit\u003cbr\u003e40 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3 for power circuit\u003cbr\u003e40 A (at \u0026lt;140 Â°F (60 Â°C)) at \u0026lt;= 440 V AC AC-3e for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uc] control circuit voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power kW\u003c\/td\u003e\n\u003ctd\u003e18.5 kW at 380...400 V AC 50\/60 Hz (AC-3)\u003cbr\u003e11 kW at 220...230 V AC 50\/60 Hz (AC-3)\u003cbr\u003e22 kW at 415...440 V AC 50\/60 Hz (AC-3)\u003cbr\u003e22 kW at 500 V AC 50\/60 Hz (AC-3)\u003cbr\u003e30 kW at 660...690 V AC 50\/60 Hz (AC-3)\u003cbr\u003e9 kW at 400 V AC 50\/60 Hz (AC-4)\u003cbr\u003e18.5 kW at 380...400 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e11 kW at 220...230 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e22 kW at 415...440 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e22 kW at 500 V AC 50\/60 Hz (AC-3e)\u003cbr\u003e30 kW at 660...690 V AC 50\/60 Hz (AC-3e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Horse Power Rating\u003c\/td\u003e\n\u003ctd\u003e5 hp at 230\/240 V AC 50\/60 Hz for 1 phase motors\u003cbr\u003e10 hp at 230\/240 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e30 hp at 575\/600 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e10 hp at 200\/208 V AC 50\/60 Hz for 3 phase motors\u003cbr\u003e3 hp at 115 V AC 50\/60 Hz for 1 phase motors\u003cbr\u003e30 hp at 460\/480 V AC 50\/60 Hz for 3 phase motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility code\u003c\/td\u003e\n\u003ctd\u003eLC1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e3 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective cover\u003c\/td\u003e\n\u003ctd\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e10 A (at 140 Â°F (60 Â°C)) for signalling circuit\u003cbr\u003e60 A (at 140 Â°F (60 Â°C)) for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIrms rated making capacity\u003c\/td\u003e\n\u003ctd\u003e140 A AC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e250 A DC for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e800 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking capacity\u003c\/td\u003e\n\u003ctd\u003e800 A at 440 V for power circuit conforming to IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Icw] rated short-time withstand current\u003c\/td\u003e\n\u003ctd\u003e320 A 104 Â°F (40 Â°C) - 10 s for power circuit\u003cbr\u003e720 A 104 Â°F (40 Â°C) - 1 s for power circuit\u003cbr\u003e72 A 104 Â°F (40 Â°C) - 10 min for power circuit\u003cbr\u003e165 A 104 Â°F (40 Â°C) - 1 min for power circuit\u003cbr\u003e100 A - 1 s for signalling circuit\u003cbr\u003e120 A - 500 ms for signalling circuit\u003cbr\u003e140 A - 100 ms for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated fuse rating\u003c\/td\u003e\n\u003ctd\u003e10 A gG for signalling circuit conforming to IEC 60947-5-1\u003cbr\u003e80 A gG at \u0026lt;= 690 V coordination type 1 for power circuit\u003cbr\u003e80 A gG at \u0026lt;= 690 V coordination type 2 for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage impedance\u003c\/td\u003e\n\u003ctd\u003e1.5 mOhm - Ith 60 A 50 Hz for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation per pole\u003c\/td\u003e\n\u003ctd\u003e2.4 W AC-3\u003cbr\u003e5.4 W AC-1\u003cbr\u003e2.4 W AC-3e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003ePower circuit 600 V CSA\u003cbr\u003ePower circuit 600 V UL\u003cbr\u003eSignalling circuit 690 V IEC 60947-1\u003cbr\u003eSignalling circuit 600 V CSA\u003cbr\u003eSignalling circuit 600 V UL\u003cbr\u003ePower circuit 690 V IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epollution degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV IEC 60947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety reliability level\u003c\/td\u003e\n\u003ctd\u003eB10d = 1369863 cycles contactor with nominal load EN\/ISO 13849-1\u003cbr\u003eB10d = 20000000 cycles contactor with mechanical load EN\/ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e10 Mcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e0.7 Mcycles 60 A AC-1 \u0026lt;= 440 V\u003cbr\u003e1.5 Mcycles 40 A AC-3 \u0026lt;= 440 V\u003cbr\u003e1.5 Mcycles 40 A AC-3e \u0026lt;= 440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit type\u003c\/td\u003e\n\u003ctd\u003eDC standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil technology\u003c\/td\u003e\n\u003ctd\u003eBuilt-in bidirectional peak limiting diode suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl circuit voltage limits\u003c\/td\u003e\n\u003ctd\u003e0.1...0.3 Uc (-40â¦158 Â°F (-40â¦70 Â°C)):drop-out DC\u003cbr\u003e0.75...1.25 Uc (-40â¦140 Â°F (-40â¦60 Â°C)):operational DC\u003cbr\u003e1...1.25 Uc (140â¦158 Â°F (60â¦70 Â°C)):operational DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush power in W\u003c\/td\u003e\n\u003ctd\u003e19 W 68 Â°F (20 Â°C))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-in power consumption in W\u003c\/td\u003e\n\u003ctd\u003e7.4 W 68 Â°F (20 Â°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e50 Â±15 % ms closing\u003cbr\u003e20 Â±20 % ms opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime constant\u003c\/td\u003e\n\u003ctd\u003e34 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating rate\u003c\/td\u003e\n\u003ctd\u003e3600 cyc\/h at 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections - terminals\u003c\/td\u003e\n\u003ctd\u003eControl circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm)\u003cbr\u003ePower circuit: lugs-ring terminals - external diameter: 0.6 in (16.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003eControl circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ã 6 mm M3.5\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5\u003cbr\u003ePower circuit 53.1 lbf.in (6 N.m) lugs-ring terminals hexagonal 0.4 in (10 mm) M6\u003cbr\u003eControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2\u003cbr\u003ePower circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts type\u003c\/td\u003e\n\u003ctd\u003eMechanically linked 1 NO + 1 NC IEC 60947-5-1\u003cbr\u003eMirror contact 1 NC IEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignalling circuit frequency\u003c\/td\u003e\n\u003ctd\u003e25...400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm for signalling circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-overlap time\u003c\/td\u003e\n\u003ctd\u003e1.5 ms on de-energisation between NC and NO contact\u003cbr\u003e1.5 ms on energisation between NC and NO contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Support\u003c\/td\u003e\n\u003ctd\u003eRail\u003cbr\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840604721374,"sku":"LC1D40A6BD-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":46487508353246,"sku":"LC1D40A6BD","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Used","offer_id":46487508386014,"sku":"LC1D40A6BD-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_828a692f-8876-4f0a-9d55-04a0237dc521.png?v=1753948919","url":"https:\/\/plc-direct.com\/en-de\/products\/lc1d40a6bd","provider":"PLC Direct","version":"1.0","type":"link"}