{"product_id":"kv-xle02","title":"KV-XLE02 Keyence","description":"\u003ch2 class=\"prd-utility-heading-3 prd-utility-marginBottom-7\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"prd-specsTable prd-utility-focusRing\" tabindex=\"0\" data-controller=\"horizontal-scroll-state scroll-to-coord\" data-action=\"resize@window-\u0026gt;horizontal-scroll-state#setOverflowing scroll-\u0026gt;horizontal-scroll-state#setScrolled\" data-horizontal-scroll-state-target=\"container\" data-horizontal-scroll-state-overflowing-class=\"is-overflowing\" data-horizontal-scroll-state-has-scrolled-class=\"is-hasScrolled\" data-scroll-to-coord-target=\"container\"\u003e\n\u003cdiv class=\"prd-utility-body-small\"\u003e\n\u003cdiv class=\"specTable-block\"\u003e\u003ctable class=\"specTable-stibo-3282397\"\u003e\u003ctbody\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001\" colspan=\"4\"\u003e\u003cp\u003eModel\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"key_att_1001\"\u003e\u003cp\u003eKV-XLE02\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_76\" colspan=\"4\"\u003e\u003cp\u003eType\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_76\"\u003e\u003cp\u003eEthernet unit\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2141\" colspan=\"4\"\u003e\u003cp\u003eConnection interface\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2141\"\u003e\u003cp\u003eRJ-45 8-pole modular connector × 2 ports\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1853\" rowspan=\"2\"\u003e\u003cp\u003eTransmission specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_1853\" colspan=\"3\"\u003e\u003cp\u003eTransmission rate\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1853\"\u003e\u003cp\u003e10BASE-T: 10 Mbps, 100BASE-TX: 100 Mbps, 1000BASE-T: 1000 Mbps\u003cbr\u003e\u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2142\" colspan=\"3\"\u003e\u003cp\u003eTransmission media\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2142\"\u003e\u003cp\u003e10BASE-T: Category 3 or higher UTP or STP (STP is recommended)\u003cbr\u003e100BASE-TX: Category 5 or higher UTP or STP (STP is recommended)\u003cbr\u003e1000BASE-T: Category 5e or higher UTP or STP (double-shielded STP is recommended)\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2143\" colspan=\"4\"\u003e\u003cp\u003eMax. cable length\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2143\"\u003e\u003cp\u003e10BASE-T: 100 m \u003cspan class=\"prd-utility-color-inch\"\u003e328.1'\u003c\/span\u003e\u003cbr\u003e100BASE-TX: 100 m \u003cspan class=\"prd-utility-color-inch\"\u003e328.1'\u003c\/span\u003e\u003cbr\u003e1000BASE-T: 100 m \u003cspan class=\"prd-utility-color-inch\"\u003e328.1'\u003c\/span\u003e\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2144\" colspan=\"4\"\u003e\u003cp\u003eMax. number of connectable hubs\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2144\"\u003e\u003cp\u003e10BASE-T: 4\u003cbr\u003e100BASE-TX: 2\u003cbr\u003e1000BASE-T: 1\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1578\" colspan=\"4\"\u003e\u003cp\u003eConnectable CPU unit\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1578\"\u003e\u003cp\u003eKV-X Series\/KV-8000A\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1779\" colspan=\"4\"\u003e\u003cp\u003eRefresh\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1779\"\u003e\u003cp\u003eAutomatic refresh, direct refresh, inter-unit synchronization refresh\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2145\" colspan=\"4\"\u003e\u003cp\u003eEthernet functions\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2145\"\u003e\u003cp\u003eKV socket communication, PLC link, PROTOCOL STUDIO, FTP server\/client, KV sensor network, Modbus server\u003csup\u003e*5\u003c\/sup\u003e, MC protocol\/SLMP\u003csup\u003e*6\u003c\/sup\u003e, etc.\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2146\" colspan=\"4\"\u003e\u003cp\u003eIndustrial networks\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2146\"\u003e\u003cp\u003eEtherNet\/IP™, PROFINET, EtherCAT®,\u003csup\u003e*7\u003c\/sup\u003e CC-Link IE Field\u003csup\u003e*8\u003c\/sup\u003e\u003csup\u003e*9\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2147\" colspan=\"4\"\u003e\u003cp\u003eEthernet function execution methods\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2147\"\u003e\u003cp\u003eLadder program, unit program (flow)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1796\" colspan=\"4\"\u003e\u003cp\u003eUnit program capacity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1796\"\u003e\u003cp\u003e3 MB (Max. number of blocks: Approx. 20000)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1797\" rowspan=\"2\"\u003e\u003cp\u003eflow\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_1797\" colspan=\"3\"\u003e\u003cp\u003eMax. number of flows\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1797\"\u003e\u003cp\u003e256\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_1798\" colspan=\"3\"\u003e\u003cp\u003eNumber of simultaneous activities\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1798\"\u003e\u003cp\u003eUnlimited\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1799\"\u003e\u003cp\u003eFlow\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_1799\" colspan=\"3\"\u003e\u003cp\u003eInternal data Memory\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1799\"\u003e\u003cp\u003e524288 words\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2148\" rowspan=\"8\"\u003e\u003cp\u003ePROTOCOL STUDIO\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2148\" colspan=\"3\"\u003e\u003cp\u003eTransmission method\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2148\"\u003e\u003cp\u003eCyclic communication: Tx + Rx, Tx only, Rx only.\u003cbr\u003eEvent communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2150\" colspan=\"3\"\u003e\u003cp\u003eMax. number of connected devices\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2150\"\u003e\u003cp\u003e16\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2172\" colspan=\"3\"\u003e\u003cp\u003eMax. number of communication commands\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2172\"\u003e\u003cp\u003e160\/320\u003csup\u003e*10\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2173\" colspan=\"3\"\u003e\u003cp\u003eMaximum number of total frames\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2173\"\u003e\u003cp\u003eRx: 160\/320\u003csup\u003e*10\u003c\/sup\u003e × 16 Tx: 160\/320\u003csup\u003e*10\u003c\/sup\u003e × 1\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2174\" colspan=\"3\"\u003e\u003cp\u003eMax. number of compared received frames\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2174\"\u003e\u003cp\u003e16 per command\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2175\" colspan=\"3\"\u003e\u003cp\u003eMaximum number of block elements\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2175\"\u003e\u003cp\u003e96 per frame\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2176\" colspan=\"3\"\u003e\u003cp\u003eTransmission data length\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2176\" rowspan=\"2\"\u003e\u003cp\u003eStandard: 1 to 2048 bytes per frame,\u003cbr\u003eExtended: 1 to 16384 bytes per frame\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2177\" colspan=\"3\"\u003e\u003cp\u003eReception data length\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_2178\" rowspan=\"8\"\u003e\u003cp\u003ePLC link\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2178\" colspan=\"3\"\u003e\u003cp\u003eCommunication patterns\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2178\"\u003e\u003cp\u003eWrite, read, transfer\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2179\" colspan=\"3\"\u003e\u003cp\u003eNumber of link settings\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2179\"\u003e\u003cp\u003e512 settings max.\u003csup\u003e*11\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2180\" colspan=\"3\"\u003e\u003cp\u003eLink data size\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2180\"\u003e\u003cp\u003e1440 words max. per setting (bit: 720 words, word: 720 words),\u003cbr\u003e737280 words max. (total) (1440 words × 512 settings)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2206\" colspan=\"3\"\u003e\u003cp\u003eData unit\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2206\"\u003e\u003cp\u003e1 word\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2207\" colspan=\"3\"\u003e\u003cp\u003eNumber of connected models\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2207\"\u003e\u003cp\u003e16 models max.\u003csup\u003e*11\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2208\" colspan=\"3\"\u003e\u003cp\u003eNumber of connected units\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2208\"\u003e\u003cp\u003e64 max.\u003csup\u003e*11\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2209\" colspan=\"3\"\u003e\u003cp\u003eTrigger types\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2209\"\u003e\u003cp\u003eCyclic\/event (64 settings max. for event\u003csup\u003e*11\u003c\/sup\u003e)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_2210\" colspan=\"3\"\u003e\u003cp\u003eUpdate interval\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_2210\"\u003e\u003cp\u003e1 to 65535 ms\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1235\" colspan=\"4\"\u003e\u003cp\u003eInternal current consumption\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_1235\"\u003e\u003cp\u003e200 mA or less\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_113\" colspan=\"4\"\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_113\"\u003e\u003cp\u003eApprox. 190 g \u003cspan class=\"prd-utility-color-inch\"\u003e6.71 oz\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-foot\"\u003e\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_1853; SPEC_SP_2142; SPEC_SP_2143; SPEC_SP_2144; SPEC_SP_2145; SPEC_SP_2146; SPEC_SP_2172; SPEC_SP_2173; SPEC_SP_2179; SPEC_SP_2207; SPEC_SP_2208; SPEC_SP_2209\" colspan=\"5\" verticalalignment=\"0\"\u003e\u003cp\u003e\u003csup\u003e*1\u003c\/sup\u003e 10 Mbps\/100 Mbps\/1000 Mbps MDI\/MDI-X automatic switching function supported\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e STP = Shielded twisted pair cable; UTP = Unshielded twisted pair cable\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e The maximum cable length refers to the distance between the KV-XLE02 and the Ethernet switch.\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e The maximum number of connection is not limited when an Ethernet switch is used.\u003cbr\u003e\u003csup\u003e*5\u003c\/sup\u003e Modbus is a registered trademark or trademark of Schneider Electric.\u003cbr\u003e\u003csup\u003e*6\u003c\/sup\u003e SLMP is a registered trademark or trademark of Mitsubishi Electric Corporation.\u003cbr\u003e\u003csup\u003e*7\u003c\/sup\u003e EtherCAT\u003csup\u003e®\u003c\/sup\u003e is fixed at 100 Mbps. It is not usable at different transmission rates.\u003cbr\u003e\u003csup\u003e*8\u003c\/sup\u003e CC-Link IE Field is fixed at 1000 Mbps. It is not usable at different transmission rates.\u003cbr\u003e\u003csup\u003e*9\u003c\/sup\u003e Industrial network trademarks\u003cbr\u003e• EtherNet\/IP™ is a registered trademark or trademark of ODVA.\u003cbr\u003e• PROFINET is a registered trademark or trademark of PROFIBUS Nutzerorganisation e.V.\u003cbr\u003e• EtherCAT\u003csup\u003e®\u003c\/sup\u003e is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany\u003cbr\u003e• CC-Link IE Field is a registered trademark or trademark of Mitsubishi Electric Corporation.\u003cbr\u003e\u003csup\u003e*10\u003c\/sup\u003e The max. is 160 when “Standard” is set for the number of communication commands in Unit Editor and 320 when “Extended” is set.\u003cbr\u003e\u003csup\u003e*11\u003c\/sup\u003e Total for one KV-XLE02 unit.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prd-specsTable-overlay prd-largeScreen-hidden\"\u003e\n\u003cdiv class=\"prd-specsTable-overlayInner\" aria-hidden=\"true\" data-action=\"click-\u0026gt;scroll-to-coord#run\" data-x-coord=\"100\"\u003e\n\u003cp class=\"prd-utility-marginBottom-2\"\u003e\n\u003csvg class=\"prd-specsTable-overlayIcon\" viewbox=\"0 0 30 30\" data-action=\"click-\u0026gt;series-header#doScroll\"\u003e\n\u003cuse xlink:href=\"#icon-horizontal-scrollable\"\u003e\u003c\/use\u003e\n\u003c\/svg\u003e\n\u003c\/p\u003e\n\u003cp class=\"prd-specsTable-overlayLabel prd-utility-body-extraSmall prd-utility-marginBottom-0\"\u003eScroll\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keyence","offers":[{"title":"Sealed Surplus","offer_id":47706194018526,"sku":"KV-XLE02-Sealed","price":454.95,"currency_code":"EUR","in_stock":true},{"title":"Never Used Surplus","offer_id":47706194051294,"sku":"KV-XLE02","price":275.95,"currency_code":"EUR","in_stock":true},{"title":"Used","offer_id":47706194084062,"sku":"KV-XLE02-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_keyence_stock_39f08f1e-f360-4246-a623-122d612ef989.png?v=1763977032","url":"https:\/\/plc-direct.com\/en-de\/products\/kv-xle02","provider":"PLC Direct","version":"1.0","type":"link"}