{"product_id":"kv-xd02","title":"KV-XD02 Keyence","description":"\u003ch2 class=\"prd-utility-heading-3 prd-utility-marginBottom-7\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"prd-specsTable prd-utility-focusRing\" tabindex=\"0\" data-controller=\"horizontal-scroll-state scroll-to-coord\" data-action=\"resize@window-\u0026gt;horizontal-scroll-state#setOverflowing scroll-\u0026gt;horizontal-scroll-state#setScrolled\" data-horizontal-scroll-state-target=\"container\" data-horizontal-scroll-state-overflowing-class=\"is-overflowing\" data-horizontal-scroll-state-has-scrolled-class=\"is-hasScrolled\" data-scroll-to-coord-target=\"container\"\u003e\n\u003cdiv class=\"prd-utility-body-small\"\u003e\n\u003cdiv class=\"specTable-block\"\u003e\u003ctable class=\"specTable-stibo-3282397\"\u003e\u003ctbody\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001\" colspan=\"4\"\u003e\u003cp\u003eModel\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"key_att_1001\"\u003e\u003cp\u003eKV-XD02 \u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22178\" rowspan=\"6\"\u003e\u003cp\u003eUnit specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22178\" colspan=\"3\"\u003e\u003cp\u003eOperating ambient temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22178\"\u003e\u003cp\u003eSystem configuration using a KV-5000\/3000 Series expansion unit: 0 to +50°C \u003cspan class=\"prd-utility-color-inch\"\u003e 32 to 122°F\u003c\/span\u003e (No freezing)\u003csup\u003e*2\u003c\/sup\u003e\u003csup\u003e*3\u003c\/sup\u003e\u003cbr\u003eSystem configuration using only a KV-8000\/7000 Series expansion unit: 0 to +55°C \u003cspan class=\"prd-utility-color-inch\"\u003e32 to 131°F\u003c\/span\u003e (No freezing)\u003csup\u003e*2\u003c\/sup\u003e\u003csup\u003e*3\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22179\" colspan=\"3\"\u003e\u003cp\u003eOperating ambient humidity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22179\"\u003e\u003cp\u003eSystem configuration using a KV-5000\/3000 Series expansion unit: 10 to 95% RH (No condensation)\u003csup\u003e*2\u003c\/sup\u003e\u003cbr\u003eSystem configuration using only a KV-8000\/7000 Series expansion unit: 5 to 95% RH (No condensation)\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22180\" colspan=\"3\"\u003e\u003cp\u003eStorage ambient temperature\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22180\"\u003e\u003cp\u003eSystem configuration using a KV-5000\/3000 Series expansion unit: −20 to +70°C \u003cspan class=\"prd-utility-color-inch\"\u003e-4 to +158°F\u003c\/span\u003e\u003csup\u003e*2\u003c\/sup\u003e\u003cbr\u003eSystem configuration using only a KV-8000\/7000 Series expansion unit: −25 to +75°C \u003cspan class=\"prd-utility-color-inch\"\u003e-13 to +167°F\u003c\/span\u003e\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22181\" colspan=\"3\"\u003e\u003cp\u003eStorage relative humidity\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22181\"\u003e\u003cp\u003eSystem configuration using a KV-5000\/3000 Series expansion unit: 10 to 95% RH (No condensation)\u003csup\u003e*2\u003c\/sup\u003e\u003cbr\u003eSystem configuration using only a KV-8000\/7000 Series expansion unit: 5 to 95% RH (No condensation)\u003csup\u003e*2\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22182\" rowspan=\"2\"\u003e\u003cp\u003ePower voltage\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_22182\" colspan=\"2\"\u003e\u003cp\u003eWhen using a power supply terminal block\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22182\"\u003e\u003cp\u003eSystem configuration using a KV-5000\/3000 Series expansion unit: 24 VDC (−10%\/+10%)\u003cbr\u003eSystem configuration using only a KV-8000\/7000 Series expansion unit: 24 VDC (−15%\/+20%)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-2\" attributeid=\"SPEC_SP_22183\" colspan=\"2\"\u003e\u003cp\u003eWhen using the KV-PU1\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22183\"\u003e\u003cp\u003eSystem configuration using a KV-5000\/3000 Series expansion unit: 100 to 240 VAC (−15%\/+10%)\u003cbr\u003eSystem configuration using only a KV-8000\/7000 Series expansion unit: 100 to 240 VAC (−15%\/+10%)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-0\" attributeid=\"SPEC_SP_22184\" rowspan=\"10\"\u003e\u003cp\u003eCommon specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22184\" colspan=\"3\"\u003e\u003cp\u003eConnectable CPU unit\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22184\"\u003e\u003cp\u003eKV-X Series\/KV-8000 Series\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22185\" colspan=\"3\"\u003e\u003cp\u003eMax. number of connectable units\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22185\"\u003e\u003cp\u003e1\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22186\" colspan=\"3\"\u003e\u003cp\u003eConnection interface\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22186\"\u003e\u003cp\u003eRJ-45 8-position modular connector × 2 ports\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22187\" colspan=\"3\"\u003e\u003cp\u003eTransmission rate\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22187\"\u003e\u003cp\u003e100 Mbps, 1000 Mbps \u003csup\u003e*4\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22188\" colspan=\"3\"\u003e\u003cp\u003eTransmission media\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22188\"\u003e\u003cp\u003e100 Mbps: Category 5 or higher UTP or STP (STP is recommended)\u003cbr\u003e1000 Mbps: Category 5e or higher UTP or STP (double-shielded STP is recommended)\u003cbr\u003e\u003csup\u003e*5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22189\" colspan=\"3\"\u003e\u003cp\u003eMaximum cable length\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22189\"\u003e\u003cp\u003e100 Mbps: 100 m \u003cspan class=\"prd-utility-color-inch\"\u003e328.1'\u003c\/span\u003e\u003cbr\u003e1000 Mbps:  100 m \u003cspan class=\"prd-utility-color-inch\"\u003e328.1'\u003c\/span\u003e\u003cbr\u003e\u003csup\u003e*6\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22190\" colspan=\"3\"\u003e\u003cp\u003eMaximum number of connectable hubs\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22190\"\u003e\u003cp\u003e100 Mbps: 2\u003cbr\u003e1000 Mbps: 1\u003cbr\u003e\u003csup\u003e*7\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22191\" colspan=\"3\"\u003e\u003cp\u003eInternal current consumption\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22191\"\u003e\u003cp\u003e500 mA or less\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22192\" colspan=\"3\"\u003e\u003cp\u003eWeight\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22192\"\u003e\u003cp\u003eApprox. 320 g \u003cspan class=\"prd-utility-color-inch\"\u003e11.30 oz\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-row\"\u003e\n\u003ctd class=\"specTable-clm-1\" attributeid=\"SPEC_SP_22193\" colspan=\"3\"\u003e\u003cp\u003eOther general specifications\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd class=\"specTable-clm-4\" attributeid=\"SPEC_SP_22193\"\u003e\u003cp\u003eSame as CPU unit\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specTable-foot\"\u003e\u003ctd class=\"specTable-clm-0\" attributeid=\"key_att_1001; SPEC_SP_22178; SPEC_SP_22179; SPEC_SP_22180; SPEC_SP_22181; SPEC_SP_22187; SPEC_SP_22188; SPEC_SP_22189; SPEC_SP_22190\" colspan=\"5\" verticalalignment=\"0\"\u003e\u003cp\u003e\u003csup\u003e*1\u003c\/sup\u003e for use with KV-X\/KV-8000 Series\u003cbr\u003e\u003csup\u003e*2\u003c\/sup\u003e Guaranteed range in which the system can be used.\u003cbr\u003e\u003csup\u003e*3\u003c\/sup\u003e Specified according to the temperature in the control panel on the lower side of the unit.\u003cbr\u003e\u003csup\u003e*4\u003c\/sup\u003e 100 Mbps\/1000 Mbps MDI\/MDI-X automatic switching function supported.\u003cbr\u003e\u003csup\u003e*5\u003c\/sup\u003e STP = Shielded twisted pair cable; UTP = Unshielded twisted pair cable.\u003cbr\u003e\u003csup\u003e*6\u003c\/sup\u003e The maximum cable length refers to the distance between the KV-XD02 and the Ethernet switch.\u003cbr\u003e\u003csup\u003e*7\u003c\/sup\u003e The maximum number is not limited when an Ethernet switch is used.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"prd-specsTable-overlay prd-largeScreen-hidden\"\u003e\n\u003cdiv class=\"prd-specsTable-overlayInner\" aria-hidden=\"true\" data-action=\"click-\u0026gt;scroll-to-coord#run\" data-x-coord=\"100\"\u003e\n\u003cp class=\"prd-utility-marginBottom-2\"\u003e\n\u003csvg class=\"prd-specsTable-overlayIcon\" viewbox=\"0 0 30 30\" data-action=\"click-\u0026gt;series-header#doScroll\"\u003e\n\u003cuse xlink:href=\"#icon-horizontal-scrollable\"\u003e\u003c\/use\u003e\n\u003c\/svg\u003e\n\u003c\/p\u003e\n\u003cp class=\"prd-specsTable-overlayLabel prd-utility-body-extraSmall prd-utility-marginBottom-0\"\u003eScroll\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keyence","offers":[{"title":"Sealed Surplus","offer_id":47799941169374,"sku":"KV-XD02-Sealed","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Never Used Surplus","offer_id":47799941202142,"sku":"KV-XD02","price":535.95,"currency_code":"EUR","in_stock":true},{"title":"Used","offer_id":47799941267678,"sku":"KV-XD02-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_keyence_stock_2968de20-3a48-4794-aa5b-d8b3b8e2abf1.png?v=1767606886","url":"https:\/\/plc-direct.com\/en-de\/products\/kv-xd02","provider":"PLC Direct","version":"1.0","type":"link"}