{"product_id":"gv-ad0110","title":"GV-AD0110 Schneider","description":"\u003cp\u003eTeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NC fault signaling contact + 1NO instantaneous auxiliary contact. Instantaneous auxiliary contact rated for operation up to 6A\/690V AC and 6A\/240V DC. Fault signaling contact rated for operation up to 2A\/240V AC and 1A\/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC).\u003c\/p\u003e\u003ch2\u003eMain\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003cbr\u003eTeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice short name\u003c\/td\u003e\n\u003ctd\u003eGVAD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or Component Type\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd\u003eGV2ME\u003cbr\u003eGV2L\u003cbr\u003eGV3P\u003cbr\u003eGV2P\u003cbr\u003eGV3L\u003cbr\u003eGV2LE\u003cbr\u003eGV2RT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eLeft side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary contacts operation\u003c\/td\u003e\n\u003ctd\u003eFault signal 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole contact composition\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eComplementary\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCharacteristic\u003c\/th\u003e\n\u003cth\u003eValue(s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e690 V IEC 60947-1\u003cbr\u003e300 V UL 508\u003cbr\u003e300 V CSA C22.2 No 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ue] rated operational voltage\u003c\/td\u003e\n\u003ctd\u003e48...690 V AC\u003cbr\u003e24...240 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ith] conventional free air thermal current\u003c\/td\u003e\n\u003ctd\u003e6 A\u003cbr\u003e2.5 A for fault signalling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e100000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching current\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum switching voltage\u003c\/td\u003e\n\u003ctd\u003e17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eGB2CB... circuit breaker\u003cbr\u003eGG fuse 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated operational power in VA\u003c\/td\u003e\n\u003ctd\u003e300 VA 48 V AC-15 100000 cycles\u003cbr\u003e414 VA 690 V AC-15 100000 cycles\u003cbr\u003e500 VA 110â¦127 V AC-15 100000 cycles\u003cbr\u003e500 VA 500 V AC-15 100000 cycles\u003cbr\u003e650 VA 440 V AC-15 100000 cycles\u003cbr\u003e720 VA 230â¦240 V AC-15 100000 cycles\u003cbr\u003e850 VA 380â¦415 V AC-15 100000 cycles\u003cbr\u003e36 VA 24 V AC-14 1000 cycles\u003cbr\u003e48 VA 48 V AC-14 1000 cycles\u003cbr\u003e72 VA 110â¦127 V AC-14 1000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated operational power in W\u003c\/td\u003e\n\u003ctd\u003e120 W 240 V DC-13 100000 cycles\u003cbr\u003e140 W 110 V DC-13 100000 cycles\u003cbr\u003e140 W 24 V DC-13 100000 cycles\u003cbr\u003e180 W 60 V DC-13 100000 cycles\u003cbr\u003e240 W 48 V DC-13 100000 cycles\u003cbr\u003e15 W 48 V DC-13 1000 cycles\u003cbr\u003e24 W 24 V DC-13 1000 cycles\u003cbr\u003e9 W 60 V DC-13 1000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e12.4 lbf.in (1.4 N.m) screw clamp terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e3.5 in (89 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e0.4 in (9.3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e2.6 in (66 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.121 lb(US) (0.055 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecolor\u003c\/td\u003e\n\u003ctd\u003eDark grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Sealed Surplus","offer_id":46840522670302,"sku":"GV-AD0110-Sealed","price":75.95,"currency_code":"EUR","in_stock":true},{"title":"Never Used Surplus","offer_id":46667315937502,"sku":"GV-AD0110","price":0.0,"currency_code":"EUR","in_stock":false},{"title":"Used","offer_id":46667315970270,"sku":"GV-AD0110-Used","price":0.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0349\/2973\/7859\/files\/new_schneider_stock_a98e5897-4a94-4a13-b178-1dc43520bab0.png?v=1753948871","url":"https:\/\/plc-direct.com\/en-de\/products\/gv-ad0110","provider":"PLC Direct","version":"1.0","type":"link"}