Filters

Static Control

214 products

Showing 121 - 144 of 214 products

Showing 121 - 144 of 214 products
View
keyence Stock Image
Keyence SJ-H156C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H156C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1560 mm 61.42" *4

No. ofelectrodes

24

Static elimination bar length

1520 mm 59.84"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1550 g 54.67 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence SJ-H156A Keyence
Sale price €2.595,95
Only 4 units left

Specifications

Model

SJ-H156A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1560 mm 61.42" *3

No. ofelectrodes

24

Static elimination bar length

1520 mm 59.84"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1550 g 54.67 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H156 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H156

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1560 mm 61.42" *3

No. ofelectrodes

36

Static elimination bar length

1520 mm 59.84"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1600 g 56.44 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H132C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H132C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1320 mm 51.97" *4

No. ofelectrodes

20

Static elimination bar length

1280 mm 50.39"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1400 g 49.38 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H132A Keyence
Sale price €1.654,95
Only 2 units left

Specifications

Model

SJ-H132A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1320 mm 51.97" *3

No. ofelectrodes

20

Static elimination bar length

1280 mm 50.39"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1400 g 49.38 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H132 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H132

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1320 mm 51.97" *3

No. ofelectrodes

30

Static elimination bar length

1280 mm 50.39"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1450 g 51.15 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H108C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H108C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1080 mm 42.52" *4

No. ofelectrodes

16

Static elimination bar length

1040 mm 40.94"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1200 g 42.33 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H108A Keyence
Sale price €1.884,95
Only 7 units left

Specifications

Model

SJ-H108A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1080 mm 42.52" *3

No. ofelectrodes

16

Static elimination bar length

1040 mm 40.94"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1200 g 42.33 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H108 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H108

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1080 mm 42.52" *3

No. ofelectrodes

24

Static elimination bar length

1040 mm 40.94"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1250 g 44.09 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H084C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H084C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

840 mm 33.07" *4

No. ofelectrodes

12

Static elimination bar length

800 mm 31.50"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

980 g 34.57 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence SJ-H084A Keyence
Sale price €1.605,95
Only 5 units left

Specifications

Model

SJ-H084A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

840 mm 33.07" *3

No. ofelectrodes

12

Static elimination bar length

800 mm 31.50"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

980 g 34.57 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H084 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H084

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

840 mm 33.07" *3

No. ofelectrodes

18

Static elimination bar length

800 mm 31.50"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1000 g 35.27 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H060C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H060C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

600 mm 23.62" *4

No. ofelectrodes

8

Static elimination bar length

560 mm 22.05"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

780 g 27.51 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence New Stock Image
Keyence SJ-H060A Keyence
Sale price €956,95
Only 10 units left

Specifications

Model

SJ-H060A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

600 mm 23.62" *3

No. ofelectrodes

8

Static elimination bar length

560 mm 22.05"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

780 g 27.51 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H060 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H060

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

600 mm 23.62" *3

No. ofelectrodes

12

Static elimination bar length

560 mm 22.05"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

800 g 28.22 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H036C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H036C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

360 mm 14.17" *4

No. ofelectrodes

4

Static elimination bar length

340 mm 13.39"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Controller

150 g 5.29 oz

Static elimination bar

500 g 17.64 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence SJ-H036A Keyence
Sale price €956,95
In stock, 17 units

Specifications

Model

SJ-H036A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

360 mm 14.17" *3

No. ofelectrodes

4

Static elimination bar length

340 mm 13.39"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Controller

150 g 5.29 oz

Static elimination bar

500 g 17.64 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H036 Keyence
Sale price €799,95
Only 3 units left

Specifications

Model

SJ-H036

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

360 mm 14.17" *3

No. ofelectrodes

6

Static elimination bar length

340 mm 13.39"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Controller

150 g 5.29 oz

Static elimination bar

510 g 17.99 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Mitsubishi Stock Image
Mitsubishi SJ-V18-5-01T-E01 Mitsubishi
Sale price€0,00
Sold Out

Specifications

Model

SJ-E01

Type

Remote controller

keyence Stock Image
Keyence OP-87600 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87599 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87526 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-87526

Applicable product

SJ-E Series

Note

This is used when there is a desire to carefully clean a single electrode probe.

keyence Stock Image
Keyence OP-87424 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-87424

Applicable product

SJ-E Series

Note

This is used when there is a desire to clean multiple electrode probes at one time.

keyence Stock Image
Keyence OP-84455 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-84455

Type

Replacement filter for the electrode probe cleaning kit 2

Number included

10

Recently viewed