Filters

Static Control

214 products

Showing 97 - 120 of 214 products

Showing 97 - 120 of 214 products
View
keyence Stock Image
Keyence OP-42218 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-42218

Type

Replacement filters for the electrode cleaning kit

Number included

10

keyence Stock Image
Keyence SJ-C5H Keyence
Sale price €657,95
Only 1 unit left

Specifications

Model

SJ-C5H

Type

10 pin to 10 pin cable

Applicable product

SJ-H036*

Length

5 m 16.4'

Keyence Stock Image
Keyence SJ-C2H Keyence
Sale price €157,95
Only 9 units left

Specifications

Model

SJ-C2H

Type

10 pin to 10 pin cable

Applicable product

SJ-H036*

Length

2 m 6.6'

keyence Stock Image
Keyence SJ-C10H Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-C10H

Type

10 pin to 10 pin cable

Applicable product

SJ-H036*

Length

10 m 32.8'

keyence Stock Image
Keyence OP-42212 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-42212

Overview

Cable for connecting the SJ-H* Series units. Three types (2-, 5-, 10- m cables) are available. This cable connects to the Relay Box as well. (Cable color: Gray)

Length

10 m 32.8'

keyence Stock Image
Keyence OP-42211 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-42211

Overview

Cable for connecting the SJ-H* Series units. Three types (2-, 5-, 10- m cables) are available. This cable connects to the Relay Box as well. (Cable color: Gray)

Length

5 m 16.4'

keyence Stock Image
Keyence OP-42210 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-42210

Overview

Cable for connecting the SJ-H* Series units. Three types (2-, 5-, 10- m cables) are available. This cable connects to the Relay Box as well. (Cable color: Gray)

Length

2 m 6.6'

keyence Stock Image
Keyence OP-84293 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-84293

Type

Tungsten electrode probes

Applicable product

Made for SJ-HA

Number included

4

Material

Tungsten

keyence Stock Image
Keyence OP-84292 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-84292

Type

Tungsten electrode probes/Tungsten accelerating electrode probes

Applicable product

Made for SJ-H

Number included

Tungsten electrode probes (four)
Tungsten accelerating electrode probes (two)

Material

Tungsten

keyence Stock Image
Keyence SJ-H300C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H300C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

3000 mm 118.11" *4

No. ofelectrodes

48

Static elimination bar length

2960 mm 116.54"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

3150 g 111.11 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H300A Keyence
Sale price €840,95
Only 1 unit left

Specifications

Model

SJ-H300A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

3000 mm 118.11" *3

No. ofelectrodes

48

Static elimination bar length

2960 mm 116.54"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

3150 g 111.11 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H300 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H300

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

3000 mm 118.11" *3

No. ofelectrodes

72

Static elimination bar length

2960 mm 116.54"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

3250 g 114.64 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H252C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H252C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

2520 mm 99.21" *4

No. ofelectrodes

40

Static elimination bar length

2480 mm 97.64"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

2700 g 95.24 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H252A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H252A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2520 mm 99.21" *3

No. ofelectrodes

40

Static elimination bar length

2480 mm 97.64"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2700 g 95.24 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H252 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H252

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2520 mm 99.21" *3

No. ofelectrodes

60

Static elimination bar length

2480 mm 97.64"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2800 g 98.77 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H228C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H228C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

2280 mm 89.76" *4

No. ofelectrodes

36

Static elimination bar length

2240 mm 88.19"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

2350 g 82.89 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H228A Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H228A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2280 mm 89.76" *3

No. ofelectrodes

36

Static elimination bar length

2240 mm 88.19"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2350 g 82.89 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H228 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H228

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2280 mm 89.76" *3

No. ofelectrodes

54

Static elimination bar length

2240 mm 88.19"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2400 g 84.66 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H204C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H204C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

2040 mm 80.31" *4

No. ofelectrodes

32

Static elimination bar length

2000 mm 78.74"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

2000 g 70.55 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H204A Keyence
Sale price €1.499,95
Only 1 unit left

Specifications

Model

SJ-H204A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2040 mm 80.31" *3

No. ofelectrodes

32

Static elimination bar length

2000 mm 78.74"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2000 g 70.55 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H204 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H204

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2040 mm 80.31" *3

No. ofelectrodes

48

Static elimination bar length

2000 mm 78.74"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2100 g 74.08 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H180C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H180C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

1800 mm 70.87" *4

No. ofelectrodes

28

Static elimination bar length

1760 mm 69.29"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

1750 g 61.73 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H180A Keyence
Sale price €1.029,95
Only 1 unit left

Specifications

Model

SJ-H180A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1800 mm 70.87" *3

No. ofelectrodes

28

Static elimination bar length

1760 mm 69.29"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1750 g 61.73 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-H180 Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H180

Type

H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1800 mm 70.87" *3

No. ofelectrodes

42

Static elimination bar length

1760 mm 69.29"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1850 g 65.26 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Recently viewed