Static Control
214 products
Showing 73 - 96 of 214 products





Specifications
Model |
OP-88020*1 |
|||
Length |
3 m 9.8 ' |
|||
Rated input |
100 to 240 VAC, 50/60 Hz |
|||
Rated output |
12 VDC, 1.5 A max. |
|||
Dimensions |
104 × 43 × 31 mm 4.09" × 1.69" × 1.22" (excl. cable area) |
|||
Weight |
Approx. 125 g |
|||
*1 A separate power supply cord is required. For details, contact your nearest KEYENCE sales office. | ||||
Scroll


Specifications
Model |
SJ-L005MT |
|||
Type |
Tube type |
|||
Voltage application method |
High frequency AC method (68 kHz) |
|||
Applied voltage |
2.5 kVAC |
|||
Ion balance |
±10 V*1 |
|||
Static elimination time |
See Data Sheet. |
|||
Air supply pressure |
0.05 to 0.5 MPa |
|||
Air supply temperature |
0 to +50°C 32 to 122°F |
|||
Connection tube |
Outer diameter: ø6 0.24", inner diameter: ø4 0.16" |
|||
Ozone concentration |
0.05 ppm or less*2 |
|||
Control input |
Static elimination stop input |
Switchable between non-voltage input and voltage input |
||
Reset input | ||||
LPC mode input | ||||
Control output |
Alarm (N.C.)/Ion level alarm (N.O.) |
Open-collector output 30 VDC or less |
||
Ratings |
Power voltage |
24 VDC ±10% (including ripple) or |
||
Current consumption |
0.2 A or less (24 VDC) |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used) |
||
Relative humidity |
35 to 65% RH (no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Material |
Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT |
|||
Weight |
Approx. 65 g |
|||
*1 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 50 mm 1.97", and air supply pressure of 0.2 MPa (typical values) | ||||
Scroll

Specifications
Model |
SJ-L005M |
|||
Type |
Nozzle type |
|||
Voltage application method |
High frequency AC method |
|||
Applied voltage |
2.2 kVAC |
|||
Ion balance |
±10 V*1 |
|||
Static elimination time |
0.4 sec.*1 |
|||
Air supply pressure |
0.05 to 0.5 MPa |
|||
Air supply temperature |
0 to +50°C 32 to 122°F |
|||
Connection tube |
Outer diameter: ø6 0.24", inner diameter: ø4 0.16" |
|||
Ozone concentration |
0.05 ppm or less*2 |
|||
Control input |
Static elimination stop input |
Switchable between non-voltage input and voltage input |
||
Reset input | ||||
LPC mode input | ||||
Control output |
Alarm (N.C.)/Ion level alarm (N.O.) |
Open-collector output 30 VDC or less |
||
Ratings |
Power voltage |
24 VDC ±10% (including ripple) or |
||
Current consumption |
0.2 A or less (24 VDC) |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used) |
||
Relative humidity |
35 to 65% RH (no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Material |
Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT |
|||
Weight |
Approx. 60 g |
|||
*1 Measurement results taken with an installation distance of 150 mm 5.91", air supply pressure of 0.2 MPa, and a nozzle angle of 90° (typical values) | ||||
Scroll

Specifications
Model |
SJ-HW02 |
|||
Type |
Extension unit for wide angle booster |
|||
Scroll

Specifications
Model |
SJ-HW01 |
|||
Type |
Wide angle booster starter unit |
|||
Scroll

Specifications
Model |
SJ-HM01 |
|||
Overview |
Used over areas where auxiliary air should not be used. |
|||
Scroll

Specifications
Model |
SJ-H02 |
|||
Power supply |
4 AA batteries |
|||
Power supply |
Operating time |
12 hours (Continuous operation)/1 year (Standby) |
||
Operation range |
Within 4m in front |
|||
Environmental resistance |
Ambient temperature |
0°C to +40°C |
||
Relative humidity |
35 to 85%RH (No condensation) |
|||
Scroll

Specifications
Model |
OP-84454 |
|||
Overview |
Used to perform maintenance on the inside wall of the electrode probe cap. |
|||
Scroll

Specifications
Model |
OP-84300 |
|||
Type |
Auxiliary support |
|||
Note |
Used to for installing SJ-H* Series. |
|||
Scroll

Specifications
Model |
OP-84299 |
|||
Type |
Electrode probe cleaning kit for SJ-H* Series |
|||
Note |
Used for maintaining the electrode probes on the SJ-H* Series. |
|||
Scroll