Filters
Best selling products
24997 products
PM556-TP-ETH:AC500,Prog.Logic Controller ,512kB,8DI/6DO-T,ETH,24VDC,1xRS485,2xOption Slot
CI542-DP: S500 Interface module. PROFIBUS slave. 8 DI: 24VDC. 8 DO: 24VDC 0.5A. 8 configurable DI/DO: 24VDC 0.5A. Extendable by up to 10 I/O modules.
TU516: S500 I/O terminal unit. For analog and 24 VDC digital modules. Spring terminals.
DA502: S500 Digital/analog I/O module. 16 DO 24VDC 0.5A. 4 AI: U, I, RTD. 2 AO: U, I. 8 configurable DI/DO: 24VDC 0.5A. 1-wire.
DA501: S500 Digital/analog I/O module. 16 DI: 24VDC. 4 AI: U, I, RTD. 2 AO: U, I. 8 configurable DI/DO: 24VDC 0.5A. 1-wire.
AX522: S500 Analog input/output module. 8 AI: U, I, RTD. 4 AO: U, I. 4 AO: U. 1-wire.
DX531: S500 Digital input/output module. 8 DI: 115..230VAC. 4 DO relay: 230VAC 3A. 2-wire
DX522: S500 Digital input/output module. 8 DI: 24VDC. 8 DO relay: 230VAC 3A. 2..3 wire.
DC532: S500 Digital input/output module. 16 DI: 24VDC. 16 configurable DI/DO: 24VDC 0.5A. 1-wire.
DC523: S500 Digital input/output module. 24 configurable DI/DO: 24VDC 0.5A. 4 aux. terminals 0 V. 4 aux. terminals 24VDC. 2..3 wire.
CM592-DP: AC500 Communication module. PROFIBUS master. 1 serial interface RS485.
TB521-ETH: AC500 Terminal base. For AC500 V2. 2 slots for communication module. Ethernet interface. 2 serial interfaces RS232/RS485.
The softstarter PSE142-600-70 has a rated maximum operational current of 142 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSE features a two-phase control with a soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR, and Event signal is available from a relay output in NO (normally open state). The PSE has functions such as current limit, kickstart, analog output, EOL, underload, and locked rotor protection. To interact with PSE, it has an Illuminated display that uses symbols to become language neutral. As an option, you can add an identical external keypad with a rating of IP66. There are three ways to communicate with PSE. It can be done by hardwire inputs Start/Stop or by Reset of fault. Another popular option is the built-in fieldbus communication Modbus RTU. You can also use an external adaptor and a Fieldbus plug. PSE is a true general pur
The softstarter PSE105-600-70 has a rated maximum operational current of 105 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSE features a two-phase control with a soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR, and Event signal is available from a relay output in NO (normally open state). The PSE has functions such as current limit, kickstart, analog output, EOL, underload, and locked rotor protection. To interact with PSE, it has an Illuminated display that uses symbols to become language neutral. As an option, you can add an identical external keypad with a rating of IP66. There are three ways to communicate with PSE. It can be done by hardwire inputs Start/Stop or by Reset of fault. Another popular option is the built-in fieldbus communication Modbus RTU. You can also use an external adaptor and a Fieldbus plug. PSE is a true general pur
The softstarter PSE85-600-70 has a rated maximum operational current of 85 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSE features a two-phase control with a soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR, and Event signal is available from a relay output in NO (normally open state). The PSE has functions such as current limit, kickstart, analog output, EOL, underload, and locked rotor protection. To interact with PSE, it has an Illuminated display that uses symbols to become language neutral. As an option, you can add an identical external keypad with a rating of IP66. There are three ways to communicate with PSE. It can be done by hardwire inputs Start/Stop or by Reset of fault. Another popular option is the built-in fieldbus communication Modbus RTU. You can also use an external adaptor and a Fieldbus plug. PSE is a true general pur
Filters