Filters
Best selling products
25644 products
MICROMASTER 420 UNFILTERED 3AC 380-480V +10/-10% 47-63HZ CONSTANT TORQUE POWER 4 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 4 KW 202 X 149 X 172 (H X W X D) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C W/O AOP/BOP
MICROMASTER 420 UNFILTERED 3AC 380-480V +10/-10% 47-63HZ CONSTANT TORQUE POWER 1.5 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 1.5 KW 173 X 73 X 149 (H X W X D) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C W/O AOP/BOP
MICROMASTER 420 without filter 200-240 V 3 AC+10/-10% 47-63 Hz Constant torque 5.5 kW Overload 150% for 60s Square-law torque 5.5 kW 245x 185x 195 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without AOP/BOP
MICROMASTER 420 without filter 200-240 V 3 AC+10/-10% 47-63 Hz Constant torque 4 kW Overload 150% for 60s Square-law torque 4 kW 245x 185x 195 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without AOP/BOP
MICROMASTER 420 UNFILTERED 1/3AC 200-240V +10/-10% 47-63HZ CONSTANT TORQUE POWER 1.5 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 1.5 KW 202 X 149 X 172 (H X W X D) PROTECTION IP20 AMBIENT TEMP.-10 TO +50 DEG C W/O AOP/BOP
MICROMASTER 420 UNFILTERED 1/3AC 200-240V +10/-10% 47-63HZ CONSTANT TORQUE POWER 0.75 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 0.75 KW 173 X 73 X 149 (H X W X D) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C W/O AOP/BOP
MICROMASTER 420 WITH BUILT IN CLASS A FILTER 3AC 380-480V +10/-10% 47-63HZ CONSTANT TORQUE POWER 7.5 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 7.5 KW 245 X 185 X 195 (H X W X D) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C W/O AOP/BOP
MICROMASTER 420 WITH BUILT IN CLASS A FILTER 3AC 200-240V +10/-10% 47-63HZ CONSTANT TORQUE POWER 5.5 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 5.5 KW 245 X 185 X 195 (H X W X D) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C W/O AOP/BOP
ICROMASTER 420 Built-in Class A filter 200-240 V 3 AC+10/-10% 47-63 Hz Constant torque 4 kW Overload 150% for 60s Square-law torque 4 kW 245x 185x 195 (HxWxD) Degree of protection IP20 Ambient temperature -10+50 °C without AOP/BOP
MICROMASTER 411 without filter 380-480 V 3 AC +10/-10 47-63 Hz Constant torque 0.75 kW Overload 150 for 60s Square-law torque 0.75 kW 135x 222x 154 (HxLxW) Degree of protection IP66 Ambient temperature -10+40 C
MICROMASTER 411 without filter 380-480 V 3 AC +10/-10% 47-63 Hz Constant torque 0.37 kW Overload 150% for 60s Square-law torque 0.37 kW 135x 222x 154 (HxLxW) Degree of protection IP66 Ambient temperature -10+40 °C
MICROMASTER 411 built-in Class B filter 380-480 V 3 AC +10/-10percent. 47-63 Hz Constant torque 3 kW Overload 150percent. for 60s Square-law torque 3 kW 170x 255x 177 (HxLxW) Degree of protection IP66 Ambient temperature -10+40 C. degrees
MICROMASTER 411 built-in Class B filter 380-480 V 3 AC +10/-10% 47-63 Hz Constant torque 2.2 kW Overload 150% for 60s Square-law torque 2.2 kW 170x 255x 177 (HxLxW) Degree of protection IP66 Ambient temperature -10+40 °C
MICROMASTER 411 built-in Class B filter 380-480 V 3 AC +10/-10% 47-63 Hz Constant torque 0.75 kW Overload 150% for 60s Square-law torque 0.75 kW 135x 222x 154 (HxLxW) Degree of protection IP66 Ambient temperature -10+40 °C
MICROMASTER 411 built-in Class B filter 380-480 V 3 AC +10/-10 47-63 Hz Constant torque 0.37 kW Overload 150 for 60s Square-law torque 0.37 kW 135x 222x 154 (HxLxW) Degree of protection IP66 Ambient temperature -10+40 C
MICROMASTER 411 ECOFAST with integrated filter class A w. PROFIBUS module left and REM module on the right 380-480 V 3 AC +10/-10% 47-63 Hz Constant torque 3 kW Overload 150% for 60s Square-law torque 3 kW 247x 279x 360 (HxLxW) degree of protection IP65 Ambient temperature 10-40 °C
MICROMASTER 410 WITHOUT FILTER 1AC 200-240 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.75 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.75 KW IP20; 175X69X102 (H X W X D) AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
MICROMASTER 410 WITHOUT FILTER 1AC 200-240 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.75 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.75 KW 150 X 69 X 138 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
MICROMASTER 410 WITHOUT FILTER 1AC 200-240 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.55 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.55 KW 150 X 69 X 138 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
MICROMASTER 410 WITHOUT FILTER 1AC 200-240 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.37 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.37 KW 150 X 69 X 118 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
MICROMASTER 410 WITHOUT FILTER 1AC 200-240 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.12 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.12 KW 150 X 69 X 118 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
MICROMASTER 410 WITHOUT FILTER 1AC 100-120 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.25 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.25 KW 150 X 69 X 118 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
MICROMASTER 410 WITHOUT FILTER 1AC 100-120 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.12 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.12 KW 150 X 69 X 118 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
MICROMASTER 410 WITH BUILT-IN CLASS B FILTER 1AC 200-240 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.55 KW OVERLOAD 150% FOR 60 S SQUARED TORQUE POWER 0.55 KW 150 X 69 X 138 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT OP
Filters