Filters

Static Control

214 products

Showing 193 - 214 of 214 products

Showing 193 - 214 of 214 products
View
keyence Stock Image
Keyence SJ-Q252 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q252

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

2600 mm 102.36" *5

Total length

2480 mm 97.64"

No. ofelectrodes

41

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2660 g 93.89 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q228 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q228

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

2360 mm 92.91" *5

Total length

2240 mm 88.19"

No. ofelectrodes

37

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2440 g 86.13 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q204 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q204

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

2120 mm 83.46" *5

Total length

2000 mm 78.74"

No. ofelectrodes

33

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2230 g 78.71 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q180 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q180

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1880 mm 74.02" *5

Total length

1760 mm 69.29"

No. ofelectrodes

29

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2010 g 70.95 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q156 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q156

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1640 mm 64.57" *5

Total length

1520 mm 59.84"

No. ofelectrodes

25

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1800 g 63.54 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q132 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q132

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1400 mm 55.12" *5

Total length

1280 mm 50.39"

No. ofelectrodes

21

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1580 g 55.77 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q108 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q108

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

1160 mm 45.67" *5

Total length

1040 mm 40.94"

No. ofelectrodes

17

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1340 g 47.30 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q084 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q084

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

920 mm 36.22" *5

Total length

800 mm 31.50"

No. ofelectrodes

13

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1120 g 39.53 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q060 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q060

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

680 mm 26.77" *5

Total length

560 mm 22.05"

No. ofelectrodes

9

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

890 g 31.41 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence SJ-Q036 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q036

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

440 mm 17.32" *5

Total length

350 mm 13.78"

No. ofelectrodes

5

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

690 g 24.35 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

keyence Stock Image
Keyence OP-88773 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88772 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88771 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88770 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88769 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88768 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88767 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence OP-87056 Keyence
Sale price $165.95
Only 7 units left

Specifications

Model

OP-87056

Type

Sensor head cable

Applicable product

IL,IG,GV-T Series head

Cable end

M8 straight - e-con

Length

2 m 6.56'

Material

Cable: Polyvinyl chloride (PVC)

Note

The cable is common to the transmitter and receiver sides, and can be used on either of them.

Weight

Approx. 80 g

keyence Stock Image
Keyence OP-88774 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88766 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88766

Rating

Input

100 to 240 VAC (50/60 Hz)

Output

24 VDC, 2.7 A

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F

Relative humidity

20 to 80% RH (no condensation)

Weight

Approx. 260 g 9.17 oz

keyence Stock Image
Keyence SJ-FB01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-FB01

Ion balance measurement

Measurement range

±50 V

Measurement accuracy

±0.5 V *1

Minimum display unit

0.1 V

Sampling cycle

0.1 s

Installation distance

50 mm 1.97" or more from SJ-F700

Temperature measurement

Measurement range

0 to +50°C 32 to 122°F

Measurement accuracy

±2°C ±3.6°F *2

Minimum display unit

0.1°C 32.18°F

Sampling cycle

0.5 s

Humidity measurement

Measurement range

10 to 85% RH

Measurement accuracy

±5% RH *2

Minimum display unit

1% RH

Sampling cycle

0.5 s

Environmental resistance

Ambient temperature

0 to +50°C 32 to +122°F

Relative humidity

10 to 85% RH (no condensation)

Material

Case: PBT
Ion-sensing plate: SUS
Display sheet: PET
Cable jacket: PVC
Connector resin: Polyester elastomer
Connector metal: Brass (nickel plated)

Weight

Approx. 30 g 1.05 oz

*1 At ±15 V or less; ±10% (indicated) for other ranges
*2 At 25°C 77°F with a relative humidity of 50%

keyence Stock Image
Keyence SJ-F700 Keyence
Sale price $1,627.32
Only 5 units left

Specifications

Model

SJ-F700

Voltage application method

Variable DC

Applied voltage

±8200 V max.

Ion balance control method

Multi-I.C.C

Ion balance

When using SJ-FB01: ±1 V *1 *2
When not using SJ-FB01: ±3 V *1 *2

Static elimination time

Approx. 0.5 s *3 *2

Installation distance

50 mm 1.97" or more

Maximum air volume

4.8 m3/min 169.51 ft3/min

Ozone density

0.005 ppm or less

Saved data

Items

Date/time, Ion level, Electrostatic charge level, Air flow, Unit status,
Various threshold values, Ion balance, Temperature, Humidity *4

Sampling cycle

0.1 s

Data history

Data saved every hour

Event log

Saved events: Errors, Warnings, Charge level threshold exceeded, Ion balance threshold
exceeded, Static elimination start/stop, Power ON/OFF, Clean operation
Charge level/ion balance outside threshold/event triggered when: Data stored for
30 seconds before and 30 seconds after an event

Other functions

Auto-clean, Sensor feedback

Input

IN1

Static elimination stop input

Bidirectional voltage input
Maximum input rating: 26.4 V, ON voltage: 18 V or higher,
OFF current: 0.1 mA or lower, ON current: 3 mA or lower (for 24 V)

IN2

Clean input

IN3

Event trigger input

Output

Photo MOS relay output, N.O./N.C. switchable,
Maximum rating: 26.4 V (50 mA), Residual voltage when ON: 1 V or less

Output

Number of outputs

3 (OUT1 to OUT3)

Functions

Assignable functions: Static elimination status, Ion level alarm, Condition alarm, Fan rotation
speed alarm, Charge level threshold exceeded, System error, Other error, Installation error
alarm, Ion balance threshold exceeded, Charged object detection, Feedback sensor error *5

Ethernet

Standard

100BASE-TX

Connector

RJ-45 8-pin connector

Rating

Power voltage

24 VDC ±10% or dedicated AC adapter (OP-88766)

Current consumption

Normal (including input/output load): 1.6 A or less
Normal (excluding input/output load): 1.45 A or less
ECO mode: 0.18 A (typical) *6

Environmental resistance

Ambient temperature

0 to +40°C 32 to +104°F (0 to +45°C 32 to +113°F when using OP-88767 or OP-88768)

Relative humidity

35 to 85% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Material

Case: PC / ABS *7, Front ventilation guard: SUS, Rear suction guard: SUS, Louvers: PC / ABS *7,
Display sheet: PC, Operation buttons: PC,
Mounting adapter insulation rubber: Silicone rubber, Bottom insulation rubber: Polyurethane,
Mounting fixture: PBT, Terminal block: LCP, Ethernet connector: Brass (tin plated),
AC adapter connector: PBT, Attached screws: Iron (trivalent chromate)

Weight

Approx. 1.2 kg 2.65 lb

*1 At a distance of 300 mm 11.81" with minimum air flow, straight louvers, and relative humidity of 65%
*2 Conducted in accordance with the following standards: ANSI-ESD-STM3.1, RCJS-TR-5-4, JIS C 61340-4-7, IEC61340-4-7ED.2
*3 At a distance of 300 mm 11.81" with maximum air flow and straight louvers
*4 Ion balance, temperature, and humidity available only when using the SJ-FB01
*5 Installation error alarm, ion balance threshold exceeded, charged object detection, and feedback sensor error available only when using the SJ-FB01
*6 Input/output not used; 24 VDC input
*7 Sustained electrostatic charge prevention grade

Recently viewed