keyence Stock Image
Keyence SJ-E108A Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-E108A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

1140 mm 44.88"*3

Total length

1040 mm 40.94"

No. ofelectrodes

17

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1270 g 44.80oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E084L Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-E084L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

920 mm 36.22"*3

Total length

800 mm 31.50"

No. ofelectrodes

13

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1070 g 37.74oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E084H Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-E084H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

900 mm 35.43"*3

Total length

800 mm 31.50"

No. ofelectrodes

25

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1100 g 38.80oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E084A Keyence
Sale price $3,409.70
Only 1 unit left

Specifications

Model

SJ-E084A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

900 mm 35.43"*3

Total length

800 mm 31.50"

No. ofelectrodes

13

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

1070 g 37.74oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E060L Keyence
Sale price $933.00
Only 1 unit left

Specifications

Model

SJ-E060L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

680 mm 26.77"*3

Total length

560 mm 22.05"

No. ofelectrodes

9

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

850 g 29.98oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E060H Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-E060H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

660 mm 25.98"*3

Total length

560 mm 22.05"

No. ofelectrodes

17

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

870 g 30.69oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E060A Keyence
Sale price $1,986.28
Only 1 unit left

Specifications

Model

SJ-E060A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

660 mm 25.98"*3

Total length

560 mm 22.05"

No. ofelectrodes

9

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

850 g 29.98oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence SJ-E036L Keyence
Sale price $1,123.29
Only 6 units left

Specifications

Model

SJ-E036L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

440 mm 17.32"*3

Total length

350 mm 13.78"

No. ofelectrodes

5

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

670 g 23.63oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-E036H Keyence
Sale price $1,990.97
Only 2 units left

Specifications

Model

SJ-E036H

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

420 mm 16.54"*3

Total length

350 mm 13.78"

No. ofelectrodes

9

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

680 g 23.99oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence SJ-E036A Keyence
Sale price $2,765.38
Only 9 units left

Specifications

Model

SJ-E036A

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

420 mm 16.54"*3

Total length

350 mm 13.78"

No. ofelectrodes

5

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

670 g 23.63oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence SJ-Q01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q01

Power source

4 AA size batteries

Operating temperature range

0 to +40°C

Operating humidity range

30-85% RH (no condensation)

Operating time

12 hours (continuous operation)/1 year (in standby mode)

Operation range

Within 4m in front
Within 2.5m and 45 degrees horizontally in relation to the front of the bar.
Within 2.5m and 30 degrees vertically in relation to the front of the bar.

Remote controller response time

During setting/batch acquisition: 1s or less
* Time for remote controller operation, unit processing, communication, and remote controller indication.

keyence Stock Image
Keyence OP-89229 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-89229

Overview

It converts NPN type I/O of the SJ-E/H/Q Series to PNP type. It cannot be used in conjunction with OP-87422.

Note

PNP Conversion Box

keyence Stock Image
Keyence OP-89052 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-89052

Overview

Use when cleaning an electrode probe.

Note

Electrode cleaning kit for SJ-Q Series

keyence Stock Image
Keyence OP-89051 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-89051

Overview

Tungsten electrode probe.

Note

Tungsten electrode probe for SJ-Q (5 supplied)

keyence Stock Image
Keyence OP-87525 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87525

Applicable product

SJ-E036

Note

This product is used to mount both sides of the SJ-E036 Series. The mounting dimensions are the same as those for the SJ-H/GL/G/V/R Series. Also, use this product when you want to perform angle adjustments (±90°).

keyence Stock Image
Keyence OP-87422 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87422

Power supply

Power voltage

24 to 36 V DC ± 10%

Power consumption

40 mA (at 24 V)/50 mA (at 36 V)

Environmental resistance

Ambient temperature

0 to 50°C

Relative humidity

30 to 80% RH (No condensation)

Weight

60 g

keyence Stock Image
Keyence OP-87417 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87416 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87416

Applicable product

SJ-E

Note

This product is used to mount both sides of the SJ-E Series. The mounting dimensions are the same as those for the SJ-H/GL/G/V/R Series. Also, use this product when you want to perform angle adjustments (±90°).

keyence Stock Image
Keyence OP-87415 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87415

Applicable product

SJ-E Series

Note

Attaching this product to the SJ-E Series prevents bending. Attach this product at equal intervals.

keyence Stock Image
Keyence OP-87414 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87414

Applicable product

SJ-E Series

Note

This is used when mounting on both sides of the SJ-Ex Series.

keyence Stock Image
Keyence SJ-C5U Keyence
Sale price $427.50
Only 5 units left

Specifications

Model

SJ-C5U

Type

10-pin I/O cable

Length

5 m 16.4'

Keyence Stock Image
Keyence SJ-C2U Keyence
Sale price $216.12
Only 8 units left

Specifications

Model

SJ-C2U

Type

10-pin I/O cable

Length

2 m 6.6'

Keyence Stock Image
Keyence SJ-C10U Keyence
Sale price $276.87
Only 9 units left

Specifications

Model

SJ-C10U

Type

10-pin I/O cable

Length

10 m 32.8'

keyence Stock Image
Keyence SJ-Q300 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-Q300

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 Vmax

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±3 V *1

Clean rating

ISO14644-1 Class 3 *2

Installation distance

10 mm 0.39" or more

Control input

Static elimination stop input

NPN open collector or non-voltage contact signal

Control output

Ion level warning, condition warning, alarm output

NPN open collector
Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication functions

Remote control

Average power consumption

Normal operation: 8.4 W,
LPC mode: 4.1 W
*3

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc1/8

Air supply pressure

0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4

Effective length

3080 mm 121.26" *5

Total length

2960 mm 116.54"

No. ofelectrodes

49

Rating

Power voltage

24 to 36 VDC±10%

Current consumption

Normal operation: 700 mA or less,
LPC mode: 170 mA (typical)
*3

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

85% RH or less (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

3090 g 109.07 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81", Air supply pressure: 0.2 MPa 29.01 PSI, Frequency: Highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH, Measurement position: Bar Center
*2 Contact us for detailed conditions.
*3 24 VDC
*4 If you wish to use the air purge function with intermittent air supply, contact us.
*5 Effective length is for static elimination range when installation distance is 100 mm 3.94".

Recently viewed