Filters

Static Control

214 products

Showing 73 - 96 of 214 products

Showing 73 - 96 of 214 products
View
keyence Stock Image
Keyence OP-88414 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88413 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88412 Keyence
Sale price $464.91
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88411 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence OP-88020 Keyence
Sale price $240.42
Only 9 units left

Specifications

Model

OP-88020*1

Length

3 m 9.8 '

Rated input

100 to 240 VAC, 50/60 Hz

Rated output

12 VDC, 1.5 A max.

Dimensions

104 × 43 × 31 mm 4.09" × 1.69" × 1.22" (excl. cable area)

Weight

Approx. 125 g

*1 A separate power supply cord is required. For details, contact your nearest KEYENCE sales office.

keyence Stock Image
Keyence OP-88410 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SJ-L005MT Keyence
Sale price $2,278.81
Only 4 units left

Specifications

Model

SJ-L005MT

Type

Tube type

Voltage application method

High frequency AC method (68 kHz)

Applied voltage

2.5 kVAC

Ion balance

±10 V*1

Static elimination time

See Data Sheet.

Air supply pressure

0.05 to 0.5 MPa

Air supply temperature

0 to +50°C 32 to 122°F

Connection tube

Outer diameter: ø6 0.24", inner diameter: ø4 0.16"

Ozone concentration

0.05 ppm or less*2

Control input

Static elimination stop input

Switchable between non-voltage input and voltage input
Non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit)
Voltage input: Maximum input rating 30 V, ON voltage 7 V or higher, OFF current 0.1 mA or lower, ON current 1.5 mA or lower (at 30 V)*3

Reset input

LPC mode input

Control output

Alarm (N.C.)/Ion level alarm (N.O.)

Open-collector output 30 VDC or less
50 mA max., residual voltage 1.5 V or less
NPN/PNP settings switchable*3*4

Ratings

Power voltage

24 VDC ±10% (including ripple) or
12 VDC (dedicated AC adapter OP-88020/87722*5)

Current consumption

0.2 A or less (24 VDC)
0.3 A or less (12 VDC)

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Material

Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT
Cable: PVC, TPE, copper alloy
Connector: PBT, brass + gold plating, phosphor bronze + gold plating, coper alloy + gold plating
Fitting: Brass + electroless Ni plating, POM, NBR

Weight

Approx. 65 g

*1 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 50 mm 1.97", and air supply pressure of 0.2 MPa (typical values)
*2 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 300 mm 11.81", and air supply pressure of 0.1 MPa (typical values)
*3 Cannot be used when the power supply is the AC adapter.
*4 To use the ion level alarm with the tube type, use it with air supply pressure of 0.3 MPa or less.
*5 Rated input of 100 to 240 VAC, 50/60 Hz

keyence Stock Image
Keyence SJ-L005M Keyence
Sale price $1,179.87
Only 5 units left

Specifications

Model

SJ-L005M

Type

Nozzle type

Voltage application method

High frequency AC method

Applied voltage

2.2 kVAC

Ion balance

±10 V*1

Static elimination time

0.4 sec.*1

Air supply pressure

0.05 to 0.5 MPa

Air supply temperature

0 to +50°C 32 to 122°F

Connection tube

Outer diameter: ø6 0.24", inner diameter: ø4 0.16"

Ozone concentration

0.05 ppm or less*2

Control input

Static elimination stop input

Switchable between non-voltage input and voltage input
Non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit)
Voltage input: Maximum input rating 30 V, ON voltage 7 V or higher, OFF current 0.1 mA or lower, ON current 1.5 mA or lower (at 30 V)*3

Reset input

LPC mode input

Control output

Alarm (N.C.)/Ion level alarm (N.O.)

Open-collector output 30 VDC or less
50 mA max., residual voltage 1.5 V or less
NPN/PNP settings switchable*3*4

Ratings

Power voltage

24 VDC ±10% (including ripple) or
12 VDC (dedicated AC adapter OP-88020/87722*5)

Current consumption

0.2 A or less (24 VDC)
0.3 A or less (12 VDC)

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Material

Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT
Cable: PVC, TPE, copper alloy
Connector: PBT, brass + gold plating, phosphor bronze + gold plating, coper alloy + gold plating
Fitting: Brass + electroless Ni plating, POM, NBR

Weight

Approx. 60 g

*1 Measurement results taken with an installation distance of 150 mm 5.91", air supply pressure of 0.2 MPa, and a nozzle angle of 90° (typical values)
*2 Measurement results taken with an installation distance of 100 mm 3.94", air supply pressure of 0.1 MPa, and a nozzle angle of 90° (typical values)
*3 Cannot be used when the power supply is the AC adapter.
*4 To use the ion level alarm with the tube type, use it with air supply pressure of 0.3 MPa or less.
*5 Rated input of 100 to 240 VAC, 50/60 Hz

keyence Stock Image
Keyence SJ-HW02 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HW02

Type

Extension unit for wide angle booster
Used to extend the auxiliary air diffusion unit.

keyence Stock Image
Keyence SJ-HW01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HW01

Type

Wide angle booster starter unit
Used to widen the static elimination range.

keyence Stock Image
Keyence SJ-HS02 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HS02

Type

Extension unit for straight air booster

keyence Stock Image
Keyence SJ-HS01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HS01

Type

Straight air booster starter unit

keyence Stock Image
Keyence SJ-HM01 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-HM01

Overview

Used over areas where auxiliary air should not be used.

keyence Stock Image
Keyence SJ-H02 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-H02

Power supply

4 AA batteries

Power supply

Operating time

12 hours (Continuous operation)/1 year (Standby)

Operation range

Within 4m in front
Within 2.5 m at angle of 45 degrees in the horizontal direction from the bar front
Within 2.5 m at angle of 30 degrees in the vertical direction from the bar front

Environmental resistance

Ambient temperature

0°C to +40°C

Relative humidity

35 to 85%RH (No condensation)

keyence Stock Image
Keyence OP-84454 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84454

Overview

Used to perform maintenance on the inside wall of the electrode probe cap.

keyence Stock Image
Keyence OP-84386 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84386

Type

End unit for air booster

keyence Stock Image
Keyence OP-84385 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84385

Type

Auxiliary support for air booster

keyence Stock Image
Keyence OP-84363 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84363

Type

Electrode probe replacement kit

keyence Stock Image
Keyence OP-84301 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84301

Type

End unit

Note

Used for installing the SJ-H* Series.

keyence Stock Image
Keyence OP-84300 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84300

Type

Auxiliary support

Note

Used to for installing SJ-H* Series.

keyence Stock Image
Keyence OP-84299 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84299

Type

Electrode probe cleaning kit for SJ-H* Series

Note

Used for maintaining the electrode probes on the SJ-H* Series.
* This cannot be used when the laminar flow assisting part is a attached.

keyence Stock Image
Keyence OP-84298 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84298

Type

exchange central supports

Applicable product

SJ-H

keyence Stock Image
Keyence OP-84297 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84297

Type

exchange side supports

Applicable product

SJ-H

keyence Stock Image
Keyence OP-84296 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84296

Type

Relay Box

Recently viewed